Displaying 101 - 120 of 156
  Number Description Initial Value Units PW TLF2000 TLF2700 TLF3200 TLF3600 TLF4000 TLF5000 TLF6003 TLF7003 TLF8003 TLF6000 TLF8000 TLF12000 TCFL2510 TCF3000L TCF1OEM TCF1000OEM Notes
100 Operating mode diaphragm vacuum pumps 1 digit 1 1 1 1 1 1 1 1 1 1 23 23 23 1 1 1 1 1 = there is only one vacuum pump 1
> 20 = there are 2 vacuum pumps, but:
21 = More ...
101 Analog inputs characteristics 0 digit 0 0 0 0 0 0 11 0 0 0 0 0 0 11 0 0 0 Starting with V2.6.1:0 = linear characteristic curves = standard1= input of anal More ...
102 switching behaviour of output 'Slow pump out' 4601 digit 1 - - - - - 4601 4601 0 0 0 0 Starting with V. 3.3.9 :
xyyz X is the minimal duration (sec.) of the closed More ...
103 Current processor temperature - gradC 0 - - - - - - - - - - - - - - - - Measurement value
104 Maximum processor temperature - gradC 0 - - - - - - - - - - - - - - - - Measurement value
105 RF-generator for MD106, MD107 1 digit 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 In case of two generators, the second one has the number 2
106 Switch-on limit for oscillator power (R8) 63 digit 0 xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx 30 IS11-IS30 = 63
IS36-IS44 = 25
IS36LC-IS44LC( = 36006, 44006) = 28
107 Correcting variable RF-forward power 1000 digit 1 xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx < 600 !! Restriction of forward power for the standard beam mode (see MD93)
108 Release code for protected machine data - digit 0 - - - - - - - - - - - - - - - -
109 not assigned 0 digit 1 xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx Starting with > V3.2.2:
Starting with V3.3.x Offset Pi
Generator software V2.2.2 More ...
110 Operating pressure 2 150 hPa 0 xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx Before V03.05.04 Gain Pi-Regulator.
Since V04.02.xx work pressure in second gas More ...
111 ? - sec 1 xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx Starting with > V3.2.2:
Generator software V2.2.2.0 required
Starting with V3.5. More ...
112 ? - % 1 xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx Starting with > V3.2.2:
Starting with V3.3.x Offset Pr
Generator software V2.2.2 More ...
113 ? 0 digit 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Starting with V4.2.x : If data unequal 0, the following applies: in automatic m More ...
114 Diamond window 0 digit 1 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 Starting with V3.6.x: in case of diamond windows, the ignition of the beam up t More ...
115 Monitoring of external beam guideway 0 sec 1 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 External beam guide gets input for collective alarm; will only be evaluated if More ...
116 Job number (see hyper term. at COM1) 65535 digit 0 65535 65535 65535 65535 65535 65535 65535 65535 65535 65535 65535 65535 65535 65535 65535 65535 Input of Job numbers in order to create a process.
117 Test 1 566 msec 0 566 566 566 566 566 566 566 566 566 566 566 566 Reserved for tests
118 Test 2 566 msec 0 566 566 566 566 566 566 566 566 566 566 566 566 Reserved for tests
119 Soft Start (TCF Only) 10 msec 1 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10