Displaying 41 - 60 of 156
  Number Description Initial Value Units PW TLF2000 TLF2700 TLF3200 TLF3600 TLF4000 TLF5000 TLF6003 TLF7003 TLF8003 TLF6000 TLF8000 TLF12000 TCFL2510 TCF3000L TCF1OEM TCF1000OEM Notes
40 Nominal power 0 volt 0.00 % 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
41 Nominal power 10 volt 100.00 % 0 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00
42 BCD interface active 0 digit 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0, 1 depending on BA and HW-expansion of control, only OEM.
Starting with V3.5. More ...
43 Maximum turbine operating pressure 200.0 hPa 1 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
44 Minimum turbine operating pressure 70.0 hPa 1 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 0.0 0.0 0.0 0.0
45 Power measuring correction value 100.0 % 0 xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx Gauge factor for measuring head in the standard beam mode (see MD95)
46 Comprehends100 % power during start-up 4230 W 0 xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx Power at 100 percent for standard beam mode (see MD96)
47 Move beam trap if beam is ignited 0 digit 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Starting with V2.7.2: from now on option because beam trap is not suited for tha More ...
48 Pressure increase when beam ignited 5.0 hPa 0 4.0 5.0 6.0 5.0 5.0 5.0 6.0 6.0 6.0 4.0 4.0 7.0 9.0 9.0 9.0 18.0 type-dependent
49 Output mirror ventilation active (nitrogen or cleaned compressed air) 0 digit 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Starting with V3.1.0:
Option coupler ventilation with flush gas (nitrogen or cle More ...
50 Analog LLS active 1 digit 1 0 0 0 0 0 0 0 0 0 0 0 0 1 2 0 0 0 = Standard
1 = per BA optional
2 = Starting with V3.5.x: for take-over of the More ...
51 LLS cycles active 1 digit 1 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 = Standard
1 = per BA optional
52 Maintenance active 1 digit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 With MD52=2 all attendance (maintenance) including the operating hours for 'Las More ...
53 Gas circulation change interval 0 h 1 0 0 0 0 0 0 0 0 0 0 0 0 72 72 72 1000 Interval with LSM =0 h. Only with KOAX-Laser > 0h according to specifications fr More ...
54 Water level check interval 100 h 1 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 Starting 05/25/2007 reduced from 432h to 100h
Starting with V4.2.x new standard More ...
55 Conductivity check intervalt 0 h 1 0 0 0 0 0 0 0 0 0 0 0 0 2160 2160 2160 2160 Starting 05/25/2007 reduced from 2160h to 0h
Starting with V4.2.x new standard v More ...
56 Reactive anode check interval 1000 h 1 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
57 Maintenance interval temperature calibration 2160 h 1 0 0 0 0 0 0 0 0 0 0 0 0 2160 2160 2160 0 Only for Koax-lasers. Timely distance between two temperature calibrations. Aft More ...
58 Tube generator 1 digit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Starting with V3.3.7: By entering the value 2, the extended tube heating time ca More ...
59 Exchange interval diaphragm vacuum pump 1 10000

a
h 1 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 Starting with V2.7.1: Value for recommendation to exchange the membrane vacuum p More ...