Number | Description | Initial Value | Units | PW | TLF2000 | TLF2700 | TLF3200 | TLF3600 | TLF4000 | TLF5000 | TLF6003 | TLF7003 | TLF8003 | TLF6000 | TLF8000 | TLF12000 | TCFL2510 | TCF3000L | TCF1OEM | TCF1000OEM | Notes | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
60 | Exchange interval diaphragm vacuum pump 2 |
10000 a |
h | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 15000 | 15000 | 15000 | 0 | 0 | 0 | 0 | Starting with V2.7.1: Value for recommendation to exchange the membrane vacuum p More ... | |
61 | Switching frequency pulse to CW for BCD-SS | 50.00 | kHz | 0 | 50.00 | 50.00 | 50.00 | 50.00 | 50.00 | 50.00 | 50.00 | 50.00 | 50.00 | 50.00 | 50.00 | 50.00 | 50.00 | 50.00 | 50.00 | 50.00 | As suggested by Control, or per customer request. | |
62 | Permanent deactivation time for laser power monitoring | 0.250 | sec | 1 | 0.250 | 0.250 | 0.250 | 0.250 | 0.250 | 0.250 | 0.250 | 0.250 | 0.250 | 0.250 | 0.250 | 0.250 | 0.250 | 0.250 | 0.250 | 0.250 | Disabling time is active if the nominal power does not change. | |
63 | Deactivation time laser power mointoring for nominal power changes. | 2.000 | sec | 1 | 2.000 | 2.000 | 2.000 | 2.000 | 2.000 | 2.000 | 2.000 | 2.000 | 2.000 | 4.000 | 4.000 | 4.000 | 2.000 | 2.000 | 2.000 | 2.000 |
small L-measuring head = 2,0sec; large L-measuring head = 4,0sec |
|
64 | Lower limit power monitoring | 0 | W | 0 | 1700 | 2300 | 2700 | 3500 | 3500 | 4400 | 5300 | ??? | ??? | 5300 | 7000 | 10000 | 1600 | 1600 | 1600 | 800 | Up to now only type-dependent, lower limit power monitoring with maximal laser n More ... | |
65 | Upper limit power monitoring | 0 | W | 0 | 2500 | 3400 | 4000 | 5000 | 5000 | 6000 | 7500 | ??? | ??? | 7500 | 10000 | 15000 | 2400 | 2400 | 2400 | 1500 | type-dependent | |
66 | Maximum pulse duty factor | 100.00 | % | 1 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | ||
67 | Vacuum pump oil change interval | 0 | h | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
With membrane vacuum pumps, this value = 0, With rotary slide valve - vacuum pu More ... |
|
68 | Sensitivity analog LLS | 0.02 | % | 0 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | As suggested by Control | |
69 | Filter weighing factor for analog LLS | 0.950 | digit | 0 | 0.950 | 0.950 | 0.950 | 0.950 | 0.950 | 0.950 | 0.950 | 0.950 | 0.950 | 0.950 | 0.950 | 0.950 | 0.950 | 0.950 | 0.950 | 0.950 | As suggested by Control | |
70 | Power regulation active | 0 | digit | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Starting with V3.2.2: Regulator Off/On = (0/1) Open regulator = 2 |
|
71 | Power regulation control amplification | 0.02 | % | 1 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.02 | 0.00 | 0.00 | 0.00 | 0.00 |
Starting with V3.2.2: Low pass f(n) = x(n) * weighting + f(n-1) * (1-weighting) More ... |
|
72 | Power regulation reset time |
1 Ab V03. |
% | 1 | 0.0025 | 0.0025 | 0.0025 | 0.0025 | 0.0025 | 0.0025 | 0.0025 | 0.0025 | 0.0025 | 0.0025 | 0.0025 | 0.0025 | 0.0025 | 0.0025 | 0.0025 | 0.0025 |
Starting with V3.2.2: Delta_gating ratio, so that the regulation deviation can b More ... |
|
73 | Delay for power control | 0.000 | sec | 1 | 2.000 | 2.000 | 2.000 | 2.000 | 2.000 | 2.000 | 2.000 | 2.000 | 2.000 | 2.000 | 2.000 | 2.000 | 2.000 | 2.000 | 2.000 | 2.000 |
Starting with V3.2.2: Time delay of the laser power regulation after nominal val More ... |
|
74 | Laser number | 56 | digit | 1 | >0 | >0 | >0 | >0 | >0 | >0 | >0 | >0 | >0 | >0 | >0 | >0 | >0 | >0 | >0 | >0 | individually | |
75 | Further calibration lines active | 0 | digit | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | Starting with V2.7.2: 0=standard calibration as previously. 4 Characteristic cu More ... | |
76 | Minimum laser power during calibration | 30.00 | W | 1 | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 | 30.00 | Starting with V2.7.2: Value is used as interruption condition for the automatic More ... | |
77 | Upper limit nominal power | 0 | W | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Starting with V3.0.6: Limiting the nominal power to a maximal value for protecti More ... |
|
78 | Water changing interval | 4320 | h | 1 | 4320 | 4320 | 4320 | 4320 | 4320 | 4320 | 4320 | 4320 | 8760 | 4320 | 4320 | 4320 | 4320 | 4320 | 4320 | 8760 |
Starting 05/25/2007, reduced from 4380h to 4320h Starting with V4.2.x new stan More ... |
|
79 | Laser On/Off active via dig. input | 0 | digit | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Starting with Version V3.0.x implemented Starting with Version V3.5.2: reaction More ... |