Number | Description | Initial Value | Units | PW | TLF2000 | TLF2700 | TLF3200 | TLF3600 | TLF4000 | TLF5000 | TLF6003 | TLF7003 | TLF8003 | TLF6000 | TLF8000 | TLF12000 | TCFL2510 | TCF3000L | TCF1OEM | TCF1000OEM | Notes | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
20 | Frequency for 0 volt voltage | 0.10 | kHz | 0 | 0.01 | 0.01 | 0.01 | 0.01 | 0.01 | 0.01 | 0.01 | 0.01 | 0.01 | 0.31 | 0.31 | 0.31 | 0.01 | 0.01 | 0.01 | 0.01 |
TLF2000-7003 = 0,01 kHz TLF6002-15000 =0,31 kHz |
|
21 | Frequency for 10 volt voltage | 20.00 | kHz | 0 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 99.00 | 99.00 | 99.00 | 99.00 | 20.00 | 20.00 | 20.00 | 99.00 |
20,00 kHz = Cutting, 99,00 kHz = Welding / Combi-Laser |
|
22 | Gas mix operation selected | 0 | digit | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 1 |
0 = Standard 1 = if Premix mode |
|
23 |
dropped since V04.02.xx |
0.00 | 1 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Until V04.01.xx: Maximumpower at alignment mode with default value = 10% |
||
24 | Minimum power in CW mode | 75.00 | % | 1 | 75.00 | 75.00 | 75.00 | 75.00 | 75.00 | 75.00 | 75.00 | 75.00 | 75.00 | 75.00 | 75.00 | 75.00 | 75.00 | 75.00 | 75.00 | 50.00 | ||
25 | Lower limit frequency | 0.01 | kHz | 0 | 0.01 | 0.01 | 0.01 | 0.01 | 0.01 | 0.01 | 0.01 | 0.01 | 0.01 | 0.31 | 0.31 | 0.31 | 0.01 | 0.01 | 0.01 | 0.01 |
small production series TLF 2000-7003 = 0,01 kHz large production series TLF6002 More ... |
|
26 | Upper limit frequency | 20.00 | kHz | 0 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 99.00 | 99.00 | 99.00 | 99.00 | 20.00 | 20.00 | 20.00 | 99.00 |
20,00 kHz = Cutting, 99,99 kHz = Welding during automatic calibration, the valu More ... |
|
27 | Upper limit laser gas flushing pressure | 170.0 | hPa | 1 | 170.0 | 170.0 | 170.0 | 170.0 | 170.0 | 170.0 | 170.0 | 170.0 | 170.0 | 170.0 | 170.0 | 170.0 | 60.0 | 60.0 | 60.0 | 60.0 | ||
28 | Lower limit laser gas flushing pressure | 120.0 | hPa | 1 | 120.0 | 120.0 | 120.0 | 120.0 | 120.0 | 120.0 | 120.0 | 120.0 | 120.0 | 120.0 | 120.0 | 120.0 | 30.0 | 30.0 | 30.0 | 30.0 | ||
29 | Number of laser gas flushing operations | 5 | digit | 0 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 0 | 0 | 0 | 0 |
small production series TLF2000-6003= 5 starting 08/10/2005: large production se More ... |
|
30 | temperature monitoring external brake resistance active | 0 | digit | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | Starting with V2.7.0: TLF6003 small: new frequency converter has external brake More ... | |
31 |
Beam delay ignited 0 ms only TLC for welding other machines: see left column |
0.080 | sec | 0 | 0.080 | 0.080 | 0.080 | 0.080 | 0.080 | 0.080 | 0.080 | 0.080 | 0.080 | 0.080 | 0.080 | 0.080 | 0.080 | 0.080 | 0.080 | 0.080 |
0 ms only for Lx050 and TLC for welding TLC, LXX20, LXX30, LXX40, LXX50, Tubemat More ... |
|
32 | Deactivation time for monitoring outcoupling mirror | 10.000 | sec | 1 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 10.000 | 10.000 | 10.000 | 10.000 |
Starting with V2.7.1: values >= 10,000 are turning monitoring off 0 = turns moni More ... |
|
33 | Aligning: Maximum value performance * time | 5000.00 | digit | 1 | 5000.00 | 5000.00 | 5000.00 | 5000.00 | 5000.00 | 5000.00 | 5000.00 | 5000.00 | 5000.00 | 5000.00 | 5000.00 | 5000.00 | 5000.00 | 5000.00 | 5000.00 | 5000.00 | Starting with V04.02.xx: Multiplication of nominal power with beam time | |
34 | Mode shot maximum beam time | 25.00 | sec | 1 | 25.00 | 25.00 | 25.00 | 25.00 | 25.00 | 25.00 | 25.00 | 25.00 | 25.00 | 25.00 | 25.00 | 25.00 | 25.00 | 25.00 | 25.00 | 25.00 | ||
35 | Analog frequency selection active | 0 | digit | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 2 | 0 | 0 |
0 = Standard 1 = LXX20, LXX30 , LXX40, LXX50 2 = starting with V3.5.x for tran More ... |
|
36 | Maximum amplitude for CW mode | 100.00 | % | 0 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | 100.00 | ||
37 | Maximum switch on time of adjusting laser | 900 | sec | 0 | 900 | 900 | 900 | 900 | 900 | 900 | 900 | 900 | 900 | 900 | 900 | 900 | 900 | 900 | 900 | 900 |
Starting with V2.6.4: continuous light, if MD37 >= 65000 Standard value = 900 |
|
38 | Offset for 'Gas mix fast' = Off | 0.0 | hPa | 1 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | ||
39 | National language is selected | 0 | digit | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | Necessary in connection with TASC300: 0=DE, 1=EN, 2=FR, 3=IT, 4=SP, 5=NL |
Laser Repair Services +1931-651-2236
Send order requests to orders@lrs.no-ip.org or Call (931)651-2236
We accept
Any reference to TRUMPF machines, part numbers etc, are for reference only. Call for current pricing.