Displaying 1 - 20 of 74
Device Error Code Description Problem Solution
DIAS H3, H7, H9 Solid DIAS Not Booting DIAS Not Booting, profibus, bitbus errors Replace DIAS
DIAS 00 Flash General error Internal processes corrupt Replace DIAS
DIAS 01 Flash Insufficient main memory Bad Memory Replace DIAS
DIAS 02 Flash Time basis setting error Internal s/w corrupt Replace DIAS
DIAS 03 Flash Interrupt-Controller number error Internal s/w corrupt Replace DIAS
DIAS 04 Flash Positive software limit The (Z) axis has reached the positive software limit Check slats, check software limit settings
DIAS 05 Flash Negative software limit The (Z) axis has reached the negative software limit Check slats, check software limit settings
DIAS 06 Flash Positive servo lag overshot The distance axis has too great a contouring error in positive direction of the More ... Check Axis for bind, or looseness. Check belt.
Replace DMP module A8.
Check fo More ...
DIAS 07 Flash Negative servo lag overshot The distance axis has too great a contouring error in negative direction of the More ... Check Axis for bind, or looseness. Check belt.
Replace DMP module A8.
Check fo More ...
DIAS 08 Flash Positive lag overshot The distanced move does not match the command sent by DIAS Check Axis for bind, or looseness. Check belt.
Replace DMP module A8.
Check fo More ...
DIAS 09 Flash Negative lag overshot The distanced move does not match the command sent by DIAS Check Axis for bind, or looseness. Check belt.

Replace DMP module A8.

Chec More ...
DIAS 10 Flash Undefined Controller State Internal state not correct Bad DIAS
DIAS 11 Flash INI file error software issue Bad DIAS
DIAS 12 Flash Errors in file software issue Bad DIAS
DIAS 13 Flash Frequency fluctuated too much. No constancy in data the feq should move incrementally in the correct ammount Bad sensor cable
Sheet moves (too thin)
bad sensor body, bad nozzle
Bad senso More ...
DIAS 14 Flash No frequency change Wrong freq values at calibration Bad sensor cable
bad sensor body
Bad sensor board
Bad DIAS
DIAS 15 Flash Bad telegram DIAS can't figure out telegram message sent Check bibus fiber cables
Clean fbir connection with Q-tip
Bad profibus cable c More ...
DIAS 16 Flash incorrect feedrate Bad feedrate programmed
DIAS 17 Flash incorrect cutting height Bad stand off prograamed
DIAS 18 Flash Incorrect piercing
height
The piercing height is not within Input the correct piercing height
the valid l More ...
Range: 0.3mm to 8.0mm
(0.3mm-20mm)