Displaying 1 - 20 of 156
  Number Description Initial Value Units PW TLF2000 TLF2700 TLF3200 TLF3600 TLF4000 TLF5000 TLF6003 TLF7003 TLF8003 TLF6000 TLF8000 TLF12000 TCFL2510 TCF3000L TCF1OEM TCF1000OEM Notes
0 Auto telegrams active 1 digit 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 = all automatic telegrams switched off
1 = all automatic telegrams are switche More ...
1 Resonator type 65535 digit 1 44000 44000 44000 44000 44000 44000 44000 oder 44000 oder 44003 48001 48001 48001 42002 42002 42002 42000 42002/42001 (Koax), 44000 (only Al-KK),44001 (Al+Cu KK), 48001 (large Resonator More ...
2 Selection of external interfaces 0 digit 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 = Bitbus ;
2 = Profibus-Slave;
255 = no interface assembly = OEM;
More ...
3 Number of blowers for gas circulation 1 digit 1 1 1 1 1 1 1 1 1 1 2 2 2 0 0 0 0 0 = no blower (Koax),
1 = 1 blower;
2 = 2 blowers
4 RF generator type 22003 digit 1 11003 15003 18003 22003 22003 36003 oder 36003 36003 ??? 44003 44003 36003 18005 18005 18005 18007 Starting with V2.5.0: 11003, 15003, 18003, 22003, 36003, 44003,
Starting with V More ...
5 Number of generators 1 digit 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1, 2, 4 Generators
6 Operating pressure 130.0 hPa 0 100.0 110.0 120.0 130.0 130.0 120.0 150.0 150.0 150.0 120.0 120.0 140.0 70.0 70.0 70.0 100.0 Up to now only type-dependent
Starting with V3.5.2: type-dependent previous sta More ...
7 Operating pressure hysteresis 1.0 hPa 0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 type-dependent
8 Operating pressure tolerance 40.0 hPa 0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 9.0 9.0 9.0 10.0
9 Switch on phase vacuum pressure 10.0 hPa 0 10.0 10.0 10.0 12.0 12.0 12.0 12.0 12.0 12.0 10.0 10.0 10.0 6.0 6.0 6.0 5.0 type-dependent
TLF2000-TLF6003 =10 hPa
TLF6002-TLF15000 = 12 hPa
large productio More ...
10 Leak test vacuum pressure 10.0 hPa 0 10.0 10.0 10.0 12.0 12.0 12.0 12.0 12.0 12.0 10.0 10.0 10.0 15.0 15.0 15.0 15.0 type-dependent
11 Leak test duration 10 min 0 10 10 10 10 10 10 10 10 10 10 10 10 720 720 720 720
12 Nominal laser power 4000 W 0 2000 2700 3200 4000 4000 5000 6000 6000 6000 6000 8000 12000 2000 2000 2000 1000 type-dependent
13 ASi Bus active 0 digit 1 0 0 0 0 0 0 0 0 0 0 0 0 2 2 1 3 ASI-Machine Data MD13
* MD13 = 0: Laser without ASI-Bus
* MD13 = 1: TCF-Laser More ...
14 Pulsing mode amplitude 10.000 V 0 10.000 10.000 10.000 10.000 10.000 10.000 10.000 10.000 10.000 10.000 10.000 10.000 10.000 10.000 10.000 10.000
15 Control type 3 digit 1 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
16 Sensitivity analog frequency preselection 0.2 % 1 - - - - - - - - - - - - 0.2 0.2 0.2 0.2 As suggested by Control
17 Filter weighing factor for analog frequency preselection 0.8 digit 0 - - - - - - - - - - - - 0.8 0.8 0.8 0.8 As suggested by Control
18 Minimum cut-off frequency 0.05 kHz 1 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.03 0.03 0.03 0.05 0.05 0.05 0.05 TLF2000-6003 = 50Hz ,
TLF6002-15000 = 30 Hz.
19 Maximum cut-off frequency 0.06 kHz 1 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.3 0.3 0.3 0.06 0.06 0.06 0.06 TLF2000-6003 = 60Hz,
TLF6002-15000 = 300 Hz.