Displaying 81 - 100 of 156
  Number Description Initial Value Units PW TLF2000 TLF2700 TLF3200 TLF3600 TLF4000 TLF5000 TLF6003 TLF7003 TLF8003 TLF6000 TLF8000 TLF12000 TCFL2510 TCF3000L TCF1OEM TCF1000OEM Notes
80 Flow indicator plausibility error 0 digit 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 If a plausibility error occurs, the machine data points to the defective flow mo More ...
81 Cooling unit address 0 digit 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Starting with V3.0.6 cooling aggregate without Profibus connection = 0: Profibus More ...
82 pulse duty factor valve + 17-Y8 'Fill gas tank' 0.00 % 1 - - - - - - - - - - - - 0.00 0.00 0.00 0.00 Starting with V3.2.2:
Display of ratio of duration of the opened valve to the to More ...
83 Selected laser warning lamps - 1 1 1 1 1 1 1 1 1 1 1 1 1 xxx xxx xxx xxx Starting with V3.4.x: 4 laser warning lamps and one machine warning lamp can be More ...
84 Reduced-power laser type 0 digit 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Starting with V3.5.2: Option: the power-reduced laser type will be defined throu More ...
85 Temp. monitoring active for deflection mirror 0 1 0 0 0 0 0 0 2 2 2 0 0 0 0 0 0 0 Starting with V3.5.2: 0 = Standard
1 = monitoring of the temperature is active. More ...
86 Reduction value 100.0 % 1 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 100.0 Starting with V3.5.2: Standard value =100,00% = maximal laser power,
only activ More ...
87 Gas saving setting 3 digit 1 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
88 Cooling unit water filter interval 4320 h 1 4320 4320 4320 4320 4320 4320 4320 4320 8760 4320 4320 4320 4320 4320 4320 4320 Starting with V3.5.4: changed from 2180 h to 2160 h.
Starting 05/25/2007 from 21 More ...
89 Mode changeover active 0 digit 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Starting with V3.0.0: Activation date for the mode change. Only if MD89 > 0, th More ...
90 Mode change-over valve pressure 1 2000.0 hPa 1 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 Starting with V3.0.0: valve pressure for Lanny-valve 1, the machine data always More ...
91 Mode change-over valve pressure 2 2000.0 hPa 1 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 Starting with V3.0.0: valve pressure for Lanny-valve 2, the machine data always More ...
92 Mode change-over valve pressure 3 2000.0 hPa 1 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 2000.0 Starting with V3.0.0: valve pressure for Lanny-valve 3, the machine data always More ...
93 Correcting variable HF forward power (R216) alternative mode 1000 digit 1 xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx 1000 1000 1000 1000 Starting with V3.0.0: Limiting of the forward power for the second selectable b More ...
94 Laser address 1 digit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Gives the address of the laser in the telegram system of the system (facility). More ...
95 Correcting factor power measuring alternative mode 100.0 % 0 xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx xxx 100.0 100.0 100.0 100.0 Starting with V3.0.0 gauge factor for the measuring head in the second selectabl More ...
96 Includes 100% power during start-up for alternative mode 4265 W 0 xxx xxx xxx xxx xxx 5230 xxx xxx xxx xxx xxx xxx 4230 4230 4230 4230 Starting with V3.0.0: power at 100 percent for second selectable mode (see MD46) More ...
97 Power monitoring lower limit alternative mode 0 W 0 1700 2300 2700 3500 3500 4400 5300 5300 5300 5300 7500 10000 0 0 0 0 Starting with V3.0.0: type-depending, lower limit power monitoring in the second More ...
98 Mask flow indicator 0 digit 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Starting with V3.0.0: after a generator flow alarm occurs, MD>0 can be set. ( More ...
99 Waiting time for "Beam On" during mode shot 0.000 sec 0 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 latest mode burn value = 0,9sec