Device | Error Code | Description | Problem | Solution | |
---|---|---|---|---|---|
DIAS | 43 Flash | Maximum frequency exceeded | The sensor exceeded the max frequency |
Inspect the sensor and cable Bad DIAS |
|
DIAS | 44 Flash |
Timeout A/D converter |
Bad DIAS | ||
DIAS | 45 Flash |
Plasma not extinguished |
The plasma suppression was unable to extinguish the plasma even with an axis sto More ... |
Check the cutting process | |
DIAS | 46 Flash | Plasma suppression inactive | Program Error | ||
DIAS | 47 Flash | Curve error | An error was detected while teaching the curve |
Sheet moved? Nozzle bad, or loose? Bad Wiring? |
|
DIAS | 48 Flash |
Sensor still in warm-up phase (max. 30s) |
You just reconnected cutting head |
Wait until it warms up 30 senconds |
|
DIAS | 49 Flash |
Command rejected due to Feed Hold |
Wiring error. Check DMP modules | ||
DIAS | 50 Flash |
Nozzle collision during controller operation |
Nozzle collision, poor cutting conditions, sensor has short-circuited |
Eliminate the collision, correct the cutting parameters, eliminate the short-cir More ... |
|
DIAS | 51 Flash |
Spatial frequency exceeded |
Ceramic part loose, damaged or incorrectly set |
Re-mount the ceramic part or, if necessary, replace it |
|
DIAS | 52 Flash |
Target position too large |
You are up too high above sheet to start curve teaching | Bring the cutting head down to sheet | |
DIAS | 53 Flash |
Manual output of analog voltage during regulation mode |
That SOB tried to move. |
Check I/O to DMP modules Replaced DIAS Replace Analog IN |
|
DIAS | 54 Flash |
PMS or PCS pierce monitor inactive |
Check PCS Sensor | ||
DIAS | 55 Flash | BiosPatch is missing | |||
DIAS | 56 Flash |
+/-15V analog output error |
The +/-15V supply to the analog is out of limits |
Bad Sensor Board Replace DIAS |
|
DIAS | 57 Flash | +15V PC error | The +15V supply to the PC is out of limits | Replace DIAS | |
DIAS | 58 Flash | -15V PC error | The -15V supply to the PC is out of limits | Replace DIAS | |
DIAS | 59 Flash |
Ground F counter error |
The ground potential of the Positive edge at digital input frequency counter has More ... |
Bad Sensor board Replaced DIAS |
|
DIAS | 60 Flash | CPU fan error | The CPU fan runs too slowly. | Replace CPU Fan | |
DIAS | 63 Flash | Configuration error |
The configuration data of the Profibus |
Check Profibus Check System SW Configuration Replace DIAS |
|
DIAS | 64 Flash | Internal watchdog is triggered |
Although the Profibus connection is ok no data is exchanged. |
Check Profibus Replace DIAS |