Displaying 41 - 60 of 66
  Device Error Code Description Problem Solution
DIAS 43 Flash Maximum frequency exceeded The sensor exceeded the max frequency Inspect the sensor and cable
Bad DIAS
DIAS 44 Flash Timeout A/D
converter
Bad DIAS
DIAS 45 Flash Plasma not
extinguished
The plasma suppression
was unable to extinguish the
plasma even with an axis sto More ...
Check the cutting process
DIAS 46 Flash Plasma suppression inactive Program Error
DIAS 47 Flash Curve error An error was detected while teaching the curve Sheet moved?
Nozzle bad, or loose?
Bad Wiring?
DIAS 48 Flash Sensor still in
warm-up phase
(max. 30s)
You just reconnected cutting head Wait until it warms up
30 senconds
DIAS 49 Flash Command rejected
due to Feed Hold
Wiring error. Check DMP modules
DIAS 50 Flash Nozzle collision
during controller
operation
Nozzle collision, poor
cutting conditions, sensor has
short-circuited
Eliminate the collision,
correct the cutting parameters,
eliminate the short-cir More ...
DIAS 51 Flash Spatial frequency
exceeded
Ceramic part loose, damaged
or incorrectly set
Re-mount the ceramic part or, if
necessary, replace it
DIAS 52 Flash Target position too
large
You are up too high above sheet to start curve teaching Bring the cutting head down to sheet
DIAS 53 Flash Manual output of
analog voltage
during regulation
mode
That SOB tried to move. Check I/O to DMP modules
Replaced DIAS
Replace Analog IN
DIAS 54 Flash PMS or PCS pierce
monitor inactive
Check PCS Sensor
DIAS 55 Flash BiosPatch is missing
DIAS 56 Flash +/-15V analog
output error
The +/-15V supply to the analog is out of limits Bad Sensor Board
Replace DIAS
DIAS 57 Flash +15V PC error The +15V supply to the PC is out of limits Replace DIAS
DIAS 58 Flash -15V PC error The -15V supply to the PC is out of limits Replace DIAS
DIAS 59 Flash Ground F counter
error
The ground potential of the
Positive edge at digital input
frequency counter has More ...
Bad Sensor board
Replaced DIAS
DIAS 60 Flash CPU fan error The CPU fan runs too slowly. Replace CPU Fan
DIAS 63 Flash Configuration error The configuration data of the
Profibus
Check Profibus
Check System SW Configuration
Replace DIAS
DIAS 64 Flash Internal watchdog is triggered Although the Profibus
connection is ok no data
is exchanged.
Check Profibus
Replace DIAS