Displaying 21 - 40 of 66
  Device Error Code Description Problem Solution
DIAS 22 Flash Telegram buffer
full
The internal telegram buffer
is full
Check Bitbus
Check Profibus
Replace DIAS
Replace TASC bitbus
DIAS 23 Flash Telegram buffer
empty
DIAS 24 Flash Timeout Replace DIAS
DIAS 25 Flash
DIAS 27 Flash
DIAS 28 Flash General interface
error
Replace DIAS
DIAS 29 Flash
DIAS 30 Flash Lag error in curve
teaching
DIAS 31 Flash
DIAS 32 Flash
DIAS 33 Flash Sensor is
unplugged
DIAS 34 Flash Sensor short-circuit
DIAS 35 Flash
DIAS 36 Flash
DIAS 37 Flash
DIAS 38 Flash
DIAS 39 Flash Temperature Exceeded It's too hot Lower temperature
DIAS 40 Flash Drift voltage
limits overshot
This is checked before moving. It's is a safety check. Z axis moved while being More ... Bad A8 Analog In module.
Defective DIAS (rare)
DIAS 41 Flash Speed limit exceeded Check drive system Loose belt, etc
DIAS 42 Flash Minimum frequency
undershot
The attached sensor did not
attain the minimum frequency
during curve teaching,
More ...
Inspect the sensor and cable
Bad DIAS